SOLD!!!!! SOLD!!!!! SOLD!!!!! ПРОДАНО!!!!! ПРОДАНО!!!!!!
GAS TURBINE
96 MW BBC - ESCHER WYSS CHP PLANT
Plant description:
Typpe of plant:
Output:
Minimum net load limit:
District heating:
Built/Commiccioned:
Fuel type:
Status: |
|
CHP
96 MW
21 MW
10% load
1978
Gas
In operation |
|
|
| Fundamentals: |
Ambient temperature:
Return hot water:
Hot water:
Cooling water: |
|
0 C
65 C
95 C
10 C |
|
Gasturbines (2x): BBC GT9 Dual Fuel
Nett capacity:
Rpm:
Generator:
Capacity:
Voltage:
Cos phi: |
|
30.770 KW Gas / 30.170 KW Oil
4475/3000
BBC WY 14L061
38,8 MVA
11.5 KV
0,85 |
|
|
Boilers (2x): NEM HRSG w/o support burners
Capacity:
Pressure live steam:
Temperature live steam:
Temperature feed water:
Spiral:
Stack temperature: |
|
68,2 mt/hr
38 bar
460 C
135 C Capacity district heating
18,6 MW
100 C |
|
Steamturbine set: Escher Wyss DT 10 (1954)
Capacity with district
heating:
Capacity w/o district heating:
Maximum steam capacity: |
|
26 MW
37,7 MW
128,2 mt/hr |
|
|
|
District heating: figures at maximum
capacity
Hot water in:
Hot water out:
Total capacity:
Capacity:
Pressure:
T in:
T out:
Steam quantity: |
|
65 C
95 C
111,6 MW
79,5 MW
0,75 bar
65 C
95 C
128,2 mt/hr |
|
|
Electric features
Voltage GT generator:
Voltage DT generator:
Voltage GT turning gear:
Voltage plant consumers: |
|
11,5 KV
6,3 KV
2,0 KV
380/220 V |
|
|
Nextinspections GT:
Nox Emissions:
Efficiency:
Availability: |
|
C- Inspections
290 gr/GJ
Operational data available on request.
per 1/4/2009 |
|
|
General: A very well maintained and operated by one of
the most renown power producing companies in Western Europe.Further
information, visits and inspections can be arranged for serious
interested parties.
|
|





|
|
|
|
|
|
|
|